To download this software requires that you read, understand, and agree to be bound by the terms and conditions of Zilog's Software License Agreement.

   

Zilog Standalone Programmer Configuration Software v2.4.0

Product Id - SD00074

Description

This Zilog Standalone Programmer (ZSP) Configuration Software installation v2.4.0 supports S3 and Z8Encore! MCU families and the part number ZUSBZSP0100ZACG. The following new features are supported:

  • Added new Programming view to program, erase, or verify target devices from within the ZSP Configuration Software. This feature requires ZSP Firmware version 2.4.0 (or later).
  • Removed the decimal format option in the serialization page. Serial Numbers are now only displayed as hexadecimal strings.
  • Modified support for F3224 devices to work around an erratum regarding the RESDCO specification being exceeded at certain DCO control codes as described UP0142 available on www.zilog.com.
  • Modified the Firmware Upgrade process to make it more resistant to power failures. The ZSP USB cable should never be disconnected while a firmware upgrade is in progress since this can leave the ZSP in an unusable state. In some instances, it might be possible to recover the ZSP Firmware should an unexpected power failure occur. For more information refer to the ZSP Firmware Upgrade document (ZSP_FW_Upgrade_Information.pdf) located in the \bin\firmware\ZSP folder.
  • Addressed the following Firmware CRs:
    • CR13639
      • After successfully programming a target with serialization enabled, both the serial number and application image are read back to ensure they were both programmed correctly. If not, a verification error (-9) is displayed on the LCD. Previously, only the target application was read back after programming and the serial number was not verified.
    • CR13641
      • ZSP FW detects an invalid checksum error (ZSP_ERR_CHECKSUM = -12) when Encore or S3 target programmed with serialization enabled if the serial number and Hex file address range overlap. No error occurs if serialization is disabled or the serial number start address is higher than the last byte in the application image
    • CR13642
      • S3 target Flash at 0x5CAE is programmed with in invalid value when serialization is enabled and the serial number is programmed at an address that's not a multiple of 0x100

This software, version 2.4.0 is free for download and is furnished as an executable file and includes a readme file; all current supporting documentation is available on the Zilog website. Please refer to the ZSP Upgrade Information guide for upgrading the ZSP firmware.

To download this software requires that you read, understand, and agree to be bound by the terms and conditions of Zilog's Software License Agreement.

View and Accept Software License

The Sample Center is managed separately
from Zilog's Customer Support services,
and therefore requires a separate login.
Acknowledged! Take me to the Sample Center.
Disable this pop-up in the future.